{"created":"2023-06-19T07:13:51.245309+00:00","id":1082,"links":{},"metadata":{"_buckets":{"deposit":"b076e8ff-cc3f-477a-836c-1492dec4747c"},"_deposit":{"created_by":24,"id":"1082","owners":[24],"pid":{"revision_id":0,"type":"depid","value":"1082"},"status":"published"},"_oai":{"id":"oai:repo.lib.tut.ac.jp:00001082","sets":["9"]},"author_link":["2145","2144"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1983-08","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"218","bibliographicPageEnd":"1372","bibliographicPageStart":"1366","bibliographicVolumeNumber":"26","bibliographic_titles":[{"bibliographic_title":"Bulletin of JSME"},{"bibliographic_title":"Bulletin of JSME","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"This paper concerns a piston pump without valves which consists of a piping system with a T-junction, two water tanks connected with both ends of the main pipe and a piston installed in the lateral pipe. Pump effect occurring in the system is examined theoretically and experimentally. The study is confined to the case that the time average flow in the main pipe is zero. The pump effect is a phenomenon that part of the energy corresponding to the time averages of kinetic energy in both of the main pipe is stored in one side of the tanks. Influences of system parameters on the pumping effect were clarified. The results obtained from a mathematical model proposed in this paper were found to be in good agreement with the experimental data.","subitem_description_type":"Abstract"}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"・rights:日本機械学会\n・rights:本文データは学協会の許諾に基づきCiNiiから複製したものである\n・relation:isVersionOf:http://ci.nii.ac.jp/naid/110002364091/\n","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"一般社団法人日本機械学会"}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"CiNii"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110002364091/","subitem_relation_type_select":"URI"}}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"00213764","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"TAKAGI, Shoji"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SAIJO, Toru"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-02-15"}],"displaytype":"detail","filename":"b00213764-0026-1366.pdf","filesize":[{"value":"712.2 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"b00213764-0026-1366","url":"https://repo.lib.tut.ac.jp/record/1082/files/b00213764-0026-1366.pdf"},"version_id":"23d387c5-db79-4d07-abd3-adc26437815e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Fluid_Vibration","subitem_subject_scheme":"Other"},{"subitem_subject":"Unsteady_Flow","subitem_subject_scheme":"Other"},{"subitem_subject":"Pump","subitem_subject_scheme":"Other"},{"subitem_subject":"Bio-Mechanics","subitem_subject_scheme":"Other"},{"subitem_subject":"T-Junction","subitem_subject_scheme":"Other"},{"subitem_subject":"Fluid_Vibration","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Unsteady_Flow","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Pump","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Bio-Mechanics","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"T-Junction","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Study of a Piston Pump without Valves : 1st Report, On a Pipe-capacity-system with a T-junction","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Study of a Piston Pump without Valves : 1st Report, On a Pipe-capacity-system with a T-junction"},{"subitem_title":"Study of a Piston Pump without Valves : 1st Report, On a Pipe-capacity-system with a T-junction","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"24","path":["9"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-02-15"},"publish_date":"2013-02-15","publish_status":"0","recid":"1082","relation_version_is_last":true,"title":["Study of a Piston Pump without Valves : 1st Report, On a Pipe-capacity-system with a T-junction"],"weko_creator_id":"24","weko_shared_id":-1},"updated":"2023-06-19T07:59:18.781717+00:00"}