{"created":"2023-06-19T07:13:58.277544+00:00","id":1201,"links":{},"metadata":{"_buckets":{"deposit":"22e4ebd5-d3ef-4ff4-8486-d472417d787e"},"_deposit":{"created_by":27,"id":"1201","owners":[27],"pid":{"revision_id":0,"type":"depid","value":"1201"},"status":"published"},"_oai":{"id":"oai:repo.lib.tut.ac.jp:00001201","sets":["9"]},"author_link":["2537","2535","2532","2533","2536","2538","2227","2534"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"1998-07-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"70","bibliographicPageEnd":"37","bibliographicPageStart":"31","bibliographic_titles":[{"bibliographic_title":"空気調和・衛生工学会論文集"},{"bibliographic_title":"Transactions of the Society of Heating,Air-Conditioning and Sanitary Engineers of Japan.","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"地球温暖化防止のため,冷凍サイクルの省動力化が求められている.二相流エゼクタを用いた冷凍サイクルは,圧縮動力の低減や冷凍サイクルの効率を向上するのに大変有用である.本研究では,二相流エゼクタサイクルの性能特性を明確化するためサイクル性能シミュレーションを行った.その結果,凝縮圧力の上昇や過冷却度が小さい場合は,エゼクタサイクルの性能向上効果が大きいことがシミュレーションによりわかった.また,実験によるエゼクタ単体性能の測定結果,エゼクタのエネルギー変換効率は約12%であることがわかった.この効率は,混合部やノズルの高効率化による向上が期待される.","subitem_description_type":"Abstract"}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"rights: 空気調和・衛生工学会 rights: 本文データは学協会の許諾に基づきCiNiiから複製したものである relation:isVersionOf: http://ci.nii.ac.jp/naid/110007996282/","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"社団法人空気調和・衛生工学会"}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"CiNii"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110007996282","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"空気調和・衛生工学会"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385275X","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"武内, 裕嗣"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山中, 隆"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"中川, 勝文"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"横関, 敦彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"TAKEUCHI, Hirotsugu","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"YAMANAKA, Takashi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"NAKAGAWA, Masafumi","creatorNameLang":"en"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"YOKOZEKI, Atsuhiko","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-07-11"}],"displaytype":"detail","filename":"k0385275X-0070-31.pdf","filesize":[{"value":"555.1 kB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"k0385275X-0070-31","url":"https://repo.lib.tut.ac.jp/record/1201/files/k0385275X-0070-31.pdf"},"version_id":"23cefd12-a1ce-4e38-bc6d-3af1e1d66073"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"シミュレーション","subitem_subject_scheme":"Other"},{"subitem_subject":"実験","subitem_subject_scheme":"Other"},{"subitem_subject":"冷凍サイクル","subitem_subject_scheme":"Other"},{"subitem_subject":"エゼクタ","subitem_subject_scheme":"Other"},{"subitem_subject":"Simulation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Experiment","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Refrigeration_Cycle","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Ejector","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"二相流エゼクタを適用した冷凍サイクル","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"二相流エゼクタを適用した冷凍サイクル"},{"subitem_title":"Refrigeration Cycle with Two-Phase Ejector","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"27","path":["9"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-07-11"},"publish_date":"2013-07-11","publish_status":"0","recid":"1201","relation_version_is_last":true,"title":["二相流エゼクタを適用した冷凍サイクル"],"weko_creator_id":"27","weko_shared_id":-1},"updated":"2023-06-19T07:56:13.175339+00:00"}