{"created":"2023-06-19T07:13:59.020982+00:00","id":1215,"links":{},"metadata":{"_buckets":{"deposit":"465cf376-b4b2-45e2-b96d-43dbefe8331f"},"_deposit":{"created_by":27,"id":"1215","owners":[27],"pid":{"revision_id":0,"type":"depid","value":"1215"},"status":"published"},"_oai":{"id":"oai:repo.lib.tut.ac.jp:00001215","sets":["9"]},"author_link":["2619","2620","2618","2616","2622","2617","2623","2621"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2009-12-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"153","bibliographicPageEnd":"56","bibliographicPageStart":"45","bibliographic_titles":[{"bibliographic_title":"空気調和・衛生工学会論文集"},{"bibliographic_title":"Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"北九州市の大学校舎建築に導入されたソーラーチムニーと地中ピットとを組み合わせた自然換気システムを対象とし,運用下におけるその性能を把握することを目的として開校後4年間に渡って実施した実測調査の結果を述べる.本報では実測対象建物の自然換気システムと補助空調システムの概要,本システムの運用状況,自然換気作用時の給排気風量の実測結果について報告する.自然換気が作用する時間は開校3年目まで増え続け,2年目から4年目の自然換気作用時間は冷房期間の33〜61%を占めた.自然換気作用時間の80%程度が夜間であった.自然換気作用時の給排気風量は,年間の全時間平均で,地中ピットからの給気量は6,000m^3/h程度,ソーラーチムニーからの排気量は4,000m^3/h程度であり,4年間を通してほぼ安定していた.この差は主に排気ファンによる影響であり,ソーラーチムニーからの排気量は風量の多い便所排気ファンの運転停止に左右されていた.給排気風量は,中間期に増加し,夏期に減少する傾向が見られた.","subitem_description_type":"Abstract"}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"rights: 空気調和・衛生工学会 rights: 本文データは学協会の許諾に基づきCiNiiから複製したものである relation:isVersionOf: http://ci.nii.ac.jp/naid/110007998497/","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"社団法人空気調和・衛生工学会"}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"CiNii"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110007998497","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"空気調和・衛生工学会"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385275X","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"品田, 宜輝"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"木村, 建一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"桂木, 宏昌"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"宋, 城基"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"SHINADA, Yoshiteru","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KIMURA, Ken-ichi","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"KATSURAGI, Hiromasa","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SONG, Sung-ki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-07-11"}],"displaytype":"detail","filename":"k0385275X-0153-45.pdf","filesize":[{"value":"1.7 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"k0385275X-0153-45","url":"https://repo.lib.tut.ac.jp/record/1215/files/k0385275X-0153-45.pdf"},"version_id":"2a345846-73d7-4200-a5b8-af55fc85b4c9"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"自然換気システム","subitem_subject_scheme":"Other"},{"subitem_subject":"ソーラーチムニー","subitem_subject_scheme":"Other"},{"subitem_subject":"地中ピット","subitem_subject_scheme":"Other"},{"subitem_subject":"自然換気量","subitem_subject_scheme":"Other"},{"subitem_subject":"実測調査","subitem_subject_scheme":"Other"},{"subitem_subject":"Natural_Ventilation_System","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Solar_Chimney","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Underground_Pit","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Air_Volume_of_Natural_Ventilation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Field_Measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"ソーラーチムニーと地中ピットとを組み合わせた自然換気システムの性能に関する4年間の実測調査 : 第1報-システムの運用状況と自然換気作用時の給排気風量","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"ソーラーチムニーと地中ピットとを組み合わせた自然換気システムの性能に関する4年間の実測調査 : 第1報-システムの運用状況と自然換気作用時の給排気風量"},{"subitem_title":"Field Investigation on the Performance of Natural Ventilation System Combined with Solar Chimney and Underground Pit for Four Years : Part 1-System Operation and Supply/Exhaust Air Volumes of Natural Ventilation","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"27","path":["9"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-07-11"},"publish_date":"2013-07-11","publish_status":"0","recid":"1215","relation_version_is_last":true,"title":["ソーラーチムニーと地中ピットとを組み合わせた自然換気システムの性能に関する4年間の実測調査 : 第1報-システムの運用状況と自然換気作用時の給排気風量"],"weko_creator_id":"27","weko_shared_id":-1},"updated":"2023-06-19T07:55:45.617220+00:00"}