{"created":"2023-06-19T07:13:59.244362+00:00","id":1218,"links":{},"metadata":{"_buckets":{"deposit":"7fe791b6-a4bd-49af-859c-cf52be60bb1a"},"_deposit":{"created_by":27,"id":"1218","owners":[27],"pid":{"revision_id":0,"type":"depid","value":"1218"},"status":"published"},"_oai":{"id":"oai:repo.lib.tut.ac.jp:00001218","sets":["9"]},"author_link":["2619","2631","2632","2633"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-03-05","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"156","bibliographicPageEnd":"18","bibliographicPageStart":"11","bibliographic_titles":[{"bibliographic_title":"空気調和・衛生工学会論文集"},{"bibliographic_title":"Transactions of the Society of Heating, Air-Conditioning and Sanitary Engineers of Japan","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"自然換気に最適なソーラーチムニーの形状を調べるために、模型実験とCFDシミュレーションにより検討を行った。その結果、チムニー水平断面積が8m^2まではチムニー水平断面積の増加に伴って換気量は増加するが、それ以上の水平断面積では換気量は増加しないことが分かった。また、排気口面積が5〜10m^2以上になると換気量はほとんど増加しないことが分かった。換気量が増加しなくなるチムニー水平断面積に対する排気口面積の断面積比はチムニー水平断面積が8m^2以下の場合1.2〜2で、8m^2以上の場合0.7〜1.2であった。また、アスペクト比が1:4、1:2、1:1のうち、1:4の換気量が最も多く、断面形状は細長い方が換気に有利であることが分かった。これらの結果から最適なチムニー形状は水平断面積8m^2、排気口10m^2、断面積比工1.2、アスペクト比1:4であることが分かった。","subitem_description_type":"Abstract"}]},"item_10001_description_6":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"rights: 空気調和・衛生工学会 rights: 本文データは学協会の許諾に基づきCiNiiから複製したものである relation:isVersionOf: http://ci.nii.ac.jp/naid/110007595413/","subitem_description_type":"Other"}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"社団法人空気調和・衛生工学会"}]},"item_10001_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"CiNii"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://ci.nii.ac.jp/naid/110007595413","subitem_relation_type_select":"URI"}}]},"item_10001_rights_15":{"attribute_name":"権利","attribute_value_mlt":[{"subitem_rights":"空気調和・衛生工学会"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0385275X","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鍋島, 佑基"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"宋, 城基"}],"nameIdentifiers":[{},{},{}]},{"creatorNames":[{"creatorName":"NABESHIMA, Yuki","creatorNameLang":"en"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"SONG, Sung-Ki","creatorNameLang":"en"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-07-11"}],"displaytype":"detail","filename":"k0385275X-0156-11.pdf","filesize":[{"value":"1.3 MB"}],"format":"application/pdf","licensetype":"license_11","mimetype":"application/pdf","url":{"label":"k0385275X-0156-11","url":"https://repo.lib.tut.ac.jp/record/1218/files/k0385275X-0156-11.pdf"},"version_id":"b202eed1-843c-4abe-97f8-7522434e0aa6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"自然換気","subitem_subject_scheme":"Other"},{"subitem_subject":"ソーラーチムニー","subitem_subject_scheme":"Other"},{"subitem_subject":"CFD","subitem_subject_scheme":"Other"},{"subitem_subject":"チムニー形状","subitem_subject_scheme":"Other"},{"subitem_subject":"アスペクト比","subitem_subject_scheme":"Other"},{"subitem_subject":"排気口面積","subitem_subject_scheme":"Other"},{"subitem_subject":"模型実験","subitem_subject_scheme":"Other"},{"subitem_subject":"Natural_Ventilation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Solar_Chimney","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"CFD","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Chimney_Form","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Aspect_Ratio","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Exhaust_Outlet","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Model_Experiment","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"模型実験とCFDシミュレーションによるソーラーチムニーの最適な形状に関する検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"模型実験とCFDシミュレーションによるソーラーチムニーの最適な形状に関する検討"},{"subitem_title":"Study on the Best Form of Solar Chimney by Model Experiment and CFD Simulation","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"27","path":["9"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-07-11"},"publish_date":"2013-07-11","publish_status":"0","recid":"1218","relation_version_is_last":true,"title":["模型実験とCFDシミュレーションによるソーラーチムニーの最適な形状に関する検討"],"weko_creator_id":"27","weko_shared_id":-1},"updated":"2023-06-19T07:55:42.531348+00:00"}