{"_buckets": {"deposit": "bd9a9df9-e8a9-49ca-9762-ce0acc4e8298"}, "_deposit": {"created_by": 27, "id": "1205", "owners": [27], "pid": {"revision_id": 0, "type": "depid", "value": "1205"}, "status": "published"}, "_oai": {"id": "oai:repo.lib.tut.ac.jp:00001205", "sets": ["9"]}, "author_link": ["2560", "2558", "2562", "2559", "2563", "2561", "2556", "2555", "2564", "2557"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2002-01-25", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "84", "bibliographicPageEnd": "41", "bibliographicPageStart": "31", "bibliographic_titles": [{"bibliographic_title": "空気調和・衛生工学会論文集"}, {"bibliographic_title": "Transactions of the Society of Heating,Air-Conditioning and Sanitary Engineers of Japan.", "bibliographic_titleLang": "en"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "近年,空調システムの最適制御,最適運転,コミッショニングが注目されているが,その検討には空調システムで使用される機器それぞれの動特性把握が不可欠である.特に室温を計測するセンサは,その出力信号で空調システムの最も主要な制御対象である室温が制御され,また間接的には熱源システムの制御動作にも影響が及ぶので非常に重要である.しかし,センサの動特性を究明した既往の研究例はほとんどない.そこで本研究では,種々の条件のもと実験室実験と現実の室内での実測を実施し,室温センサの時定数を見いだし検討を加えた.", "subitem_description_type": "Abstract"}]}, "item_10001_description_6": {"attribute_name": "内容記述", "attribute_value_mlt": [{"subitem_description": "rights: 空気調和・衛生工学会 rights: 本文データは学協会の許諾に基づきCiNiiから複製したものである relation:isVersionOf: http://ci.nii.ac.jp/naid/110007995919/", "subitem_description_type": "Other"}]}, "item_10001_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "社団法人空気調和・衛生工学会"}]}, "item_10001_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_name": [{"subitem_relation_name_text": "CiNii"}], "subitem_relation_type_id": {"subitem_relation_type_id_text": "http://ci.nii.ac.jp/naid/110007995919", "subitem_relation_type_select": "URI"}}]}, "item_10001_rights_15": {"attribute_name": "権利", "attribute_value_mlt": [{"subitem_rights": "空気調和・衛生工学会"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0385275X", "subitem_source_identifier_type": "ISSN"}]}, "item_10001_version_type_20": {"attribute_name": "著者版フラグ", "attribute_value_mlt": [{"subitem_version_resource": "http://purl.org/coar/version/c_970fb48d4fbd8a85", "subitem_version_type": "VoR"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "林, 茂広"}], "nameIdentifiers": [{"nameIdentifier": "2555", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉田, 治典"}], "nameIdentifiers": [{"nameIdentifier": "2556", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鈴木, 正美"}], "nameIdentifiers": [{"nameIdentifier": "2557", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡田, 勝行"}], "nameIdentifiers": [{"nameIdentifier": "2558", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "松本, 博"}], "nameIdentifiers": [{"nameIdentifier": "2559", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "HAYASHI, Shigehiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "2560", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "YOSHIDA, Harunori", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "2561", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "SUZUKI, Masami", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "2562", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "OKADA, Katsuyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "2563", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "MATSUMOTO, Hiroshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "2564", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2013-07-11"}], "displaytype": "detail", "download_preview_message": "", "file_order": 0, "filename": "k0385275X-0084-31.pdf", "filesize": [{"value": "922.1 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_11", "mimetype": "application/pdf", "size": 922100.0, "url": {"label": "k0385275X-0084-31", "url": "https://repo.lib.tut.ac.jp/record/1205/files/k0385275X-0084-31.pdf"}, "version_id": "03e8056d-5df3-40ec-87b4-ad27f767b5c6"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "室温センサ", "subitem_subject_scheme": "Other"}, {"subitem_subject": "自動制御", "subitem_subject_scheme": "Other"}, {"subitem_subject": "時定数", "subitem_subject_scheme": "Other"}, {"subitem_subject": "実験", "subitem_subject_scheme": "Other"}, {"subitem_subject": "同定", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Room_air_temperature_sensor", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Automatic_control", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Time_constant", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Experiment", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}, {"subitem_subject": "Identfication", "subitem_subject_language": "en", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "空調制御用室内温度センサの時定数に関する研究", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "空調制御用室内温度センサの時定数に関する研究"}, {"subitem_title": "A Study on Time Constant of the Room Air Temperature Sensors used for Air Conditioning Control System", "subitem_title_language": "en"}]}, "item_type_id": "10001", "owner": "27", "path": ["9"], "permalink_uri": "https://repo.lib.tut.ac.jp/records/1205", "pubdate": {"attribute_name": "公開日", "attribute_value": "2013-07-11"}, "publish_date": "2013-07-11", "publish_status": "0", "recid": "1205", "relation": {}, "relation_version_is_last": true, "title": ["空調制御用室内温度センサの時定数に関する研究"], "weko_shared_id": -1}
空調制御用室内温度センサの時定数に関する研究
https://repo.lib.tut.ac.jp/records/1205
https://repo.lib.tut.ac.jp/records/12054b5acd35-6389-4702-b220-aa32c3fa0441
名前 / ファイル | ライセンス | アクション |
---|---|---|
![]() |
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-07-11 | |||||
タイトル | ||||||
タイトル | 空調制御用室内温度センサの時定数に関する研究 | |||||
タイトル | ||||||
言語 | en | |||||
タイトル | A Study on Time Constant of the Room Air Temperature Sensors used for Air Conditioning Control System | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ | journal article | |||||
著者 |
林, 茂広
× 林, 茂広× 吉田, 治典× 鈴木, 正美× 岡田, 勝行× 松本, 博× HAYASHI, Shigehiro× YOSHIDA, Harunori× SUZUKI, Masami× OKADA, Katsuyuki× MATSUMOTO, Hiroshi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 近年,空調システムの最適制御,最適運転,コミッショニングが注目されているが,その検討には空調システムで使用される機器それぞれの動特性把握が不可欠である.特に室温を計測するセンサは,その出力信号で空調システムの最も主要な制御対象である室温が制御され,また間接的には熱源システムの制御動作にも影響が及ぶので非常に重要である.しかし,センサの動特性を究明した既往の研究例はほとんどない.そこで本研究では,種々の条件のもと実験室実験と現実の室内での実測を実施し,室温センサの時定数を見いだし検討を加えた. | |||||
内容記述 | ||||||
内容記述タイプ | Other | |||||
内容記述 | rights: 空気調和・衛生工学会 rights: 本文データは学協会の許諾に基づきCiNiiから複製したものである relation:isVersionOf: http://ci.nii.ac.jp/naid/110007995919/ | |||||
書誌情報 |
空気調和・衛生工学会論文集 en : Transactions of the Society of Heating,Air-Conditioning and Sanitary Engineers of Japan. 号 84, p. 31-41, 発行日 2002-01-25 |
|||||
出版者 | ||||||
出版者 | 社団法人空気調和・衛生工学会 | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0385275X | |||||
権利 | ||||||
権利情報 | 空気調和・衛生工学会 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://ci.nii.ac.jp/naid/110007995919 | |||||
関連名称 | CiNii | |||||
著者版フラグ | ||||||
出版タイプ | VoR | |||||
キーワード | ||||||
主題 | 室温センサ | |||||
キーワード | ||||||
主題 | 自動制御 | |||||
キーワード | ||||||
主題 | 時定数 | |||||
キーワード | ||||||
主題 | 実験 | |||||
キーワード | ||||||
主題 | 同定 | |||||
キーワード | ||||||
主題 | Room_air_temperature_sensor | |||||
キーワード | ||||||
主題 | Automatic_control | |||||
キーワード | ||||||
主題 | Time_constant | |||||
キーワード | ||||||
主題 | Experiment | |||||
キーワード | ||||||
主題 | Identfication |