WEKO3
アイテム
ヘッドスペース法を用いた血中一酸化炭素濃度測定の有効性
https://repo.lib.tut.ac.jp/records/1178
https://repo.lib.tut.ac.jp/records/11781a69d8fd-5e4b-4715-a8d2-164c8f27b8d9
名前 / ファイル | ライセンス | アクション |
---|---|---|
hibarino03507 (654.3 kB)
|
Item type | 紀要論文(ELS) / Departmental Bulletin Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2013-06-27 | |||||
タイトル | ||||||
タイトル | ヘッドスペース法を用いた血中一酸化炭素濃度測定の有効性 | |||||
タイトル | ||||||
タイトル | Validity for Measuring Blood CO Concentration by Head Space Method | |||||
言語 | en | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | departmental bulletin paper | |||||
ページ属性 | ||||||
内容記述タイプ | Other | |||||
内容記述 | P(論文) | |||||
論文名よみ | ||||||
その他のタイトル | ヘッド スペース ホウ ヲ モチイタ ケッチュウ イッサンカタンソ ノウド ソクテイ ノ ユウコウセイ | |||||
著者 |
安田, 好文
× 安田, 好文× 竹内, 隼人× 齊戸, 美弘× Yasuda, Yoshifumi× Takeuchi, Hayato× Saito, Yoshihiro |
|||||
著者名よみ |
ヤスダ, ヨシフミ
× ヤスダ, ヨシフミ× タケウチ, ハヤト× サイト, ヨシヒロ |
|||||
著者所属(日) | ||||||
値 | 豊橋技術科学大学 | |||||
著者所属(英) | ||||||
言語 | en | |||||
値 | Toyohashi University of Technology | |||||
抄録(英) | ||||||
内容記述タイプ | Other | |||||
内容記述 | Carbon monoxide (CO) concentration in the blood is measured by a headspace method with a gas-chromatography (HS-GC) and/or a CO-oximeter. However, the deficiencies of using HS-GC, especially on blood CO analysis, are not well documented. In the present study the effect of these deficiencies and the agreement of the results between the HS-GC and CO-oximeter methods were examined. Results indicated, in the application of HS-GC for blood CO analysis, that the TRIlyzer, a simplified gas chromatograph used in this study, showed a high linearity and reproducibility. The use of a surfactant such as Triton enhanced destruction of the plasma membrane of the erythrocytes and thereby increased blood CO values. Furthermore, an alkaline buffer solution provided higher blood CO values compared with those of an acid buffer solution. Correlation analysis between the results obtained by HS-GC and CO-oximeter on four subjects, including smokers and non-smokers, also revealed a significant relationship (r= 0.954) between them. However, the correlation coefficient (r) between CO concentrations during and after exercise measured by HS-GC and CO-oximeter on each subject showed a negative correlation for three of the four subjects. It is suggested that, in the application of HS-GC, a surfactant and an alkaline buffer solution should be used in the blood CO analysis, but discrepancies still remain between the values obtained by HS-GC and CO-oximeter. Therefore, further studies will be required to obtain clear agreement between the methods. |
|||||
雑誌書誌ID | ||||||
収録物識別子タイプ | NCID | |||||
収録物識別子 | AN00208381 | |||||
書誌情報 |
雲雀野 en : The Lark Hill 巻 35, p. 47-55, 発行日 2013-03-31 |